Terms of Motor Nameplate
Motor Manufacturer
This is the trade name of the company which manufactured the motor Some times the company's home city, and perhaps even an address and/or telephone number will be on the nameplate.
Mod. (Model)
Some companies distinguish between a Model number and a Type number. In any event, this is the key number that you need if you want to contact the manufacturer.
Ser. (Serial Number)
Serial numbers are important because they often contain "date codes". This is information which helps the manufacturer determine when the motor was manufactured. Since many motors have multiple revisions through their lifecycle .
HP (Horsepower) or KW (kilowatts)
If you are using an American made motor or an older English or Canadian motor, it will probably be rated in Horsepower. European and Asian motors are usually rated in kilowatts .
Rule to remember: 1 HP = 3/4 KW (more precisely 746 watts).
Second rule to remember: Volts x Amps = Watts.
RPM (Revolutions per Minute)
The number of times each minute that the shaft turns on its axis. This is rated at the Hertz listed. Typical values are 1750, 1450, 3450, etc. If more than one speed is listed, this indicates a multi-speed motor.
V (Volts)
The operating voltage of the motor. If the motor is an AC motor, this will typically be 115, 230, 380, 480, 575, or some number reasonably close to these figures. DC motors will have numbers such as 24, 48, 90, 180, or other voltage, and will usually say "VDC".
ARM. (Armature)
This is the maximum voltage which can be applied to the armature of a DC motor. Typical values are 90 or 180 VDC. Amperage will often be listed.
FLD. (Field)
This is the voltage which should be applied to the field of a DC motor. Typical values are 100, 150, 200 VDC. Amperage will often be listed.
Phases
This will indicate whether the motor operates from single phase or three phase electricity.
Hz (Hertz or Cycles per Second)
This indicates whether the motor is designed for operation on 50 or 60 Hertz electricity. Motors consume about 15% more amps when operated at 50 Hertz than at 60 Hertz. Thus, most 50 Hertz-designed motors will operate on 60 Hertz systems with little difficulty, but you will pay more for this.
A (Amps)
The amount of current consumed by the motor.
Fr (Frame)
The physical dimensional standard to which the motor adheres. This is critical when it is necessary to locate a mechanical replacement for an old motor.
Delta Winding
Many motors have two different ways of connecting the windings to three phase power. The delta winding usually gives higher speed with lower starting torque. In essence, this is cruising gear
Star or Wye Winding
Many motors have two different ways of connecting the windings to three phase power. The delta winding usually gives higher starting torque with lower top speed. In essence, this is first gear.
Likewise there are lots of necessary information's can get form this motor by carefully get idea on the name plate of the relevant motor.